![]() Manufacturing loadcells since 1972 |
SY011 Loadcell Amplifier |
Home | Profile | News | Products | Codes | Applications | Stock | Information | Contact |
|
|
This loadcell amplifier is designed for use with strain gauge loadcells. It provides industry standard current or voltage outputs for accurate interfacing of loadcells with control and monitoring systems. This amplifier is ideally suited to engineering applications. Its small size makes it easy to mount inside existing equipment. The voltage output version of the amplifier has a bi-polar output for use with bi-directional loadcells even though it is powered from a uni-polar supply. The amplifier is easily calibrated using non-interactive zero and span trimmers. When it is purchased with a loadcell it will be calibrated for use with the loadcell. If the SY011 is supplied with a loadcell it will normally be calibrated to read the loadcell output in the same force units as the loadcell calibration. A traceable system certificate will be supplied for the amplifier and loadcell combination. This amplifier can be used with any of our loadcells. Details of our loadcell families can be found in the Product Guide. |
Output | Current version: 4 to 20mA, loop resistance <400Ω (24V supply) |
Voltage version: ±5V or ± 10V, load resistance >10kΩ | |
Sensitivity | Factory set between 0.5 and 100mV/V |
Non-linearity - typical | ±0.05% of full range |
Drift - typical | Zero: 0.5µV/°C at the input |
Span: 80ppm/°C | |
Supply requirements | Current version: Nominal 24Vdc (12 to 30Vdc) |
Voltage version: Nominal 15Vdc (14 to 16Vdc) | |
Maximum supply current | 185mA |
Loadcell supply | 5Vdc or 10Vdc (factory set) |
Operating Temperature | 0 to +50°C |
Case material | ABS |
Case dimensions | 60 x 48.5 x 18 mm (including terminals) |
Loadcell supply | Module supply | |
---|---|---|
15Vdc | 24Vdc | |
5Vdc | 75mA | 35mA |
10Vdc | 150mA | 50mA |
SY011 | A | B | C | D |
---|---|---|---|---|
Replace A, B, C and D with the required codes from the list below. | ||||
A | Basic type | |||
V for voltage output, I for current output. | ||||
B | Amplifier output | |||
005 for ±5, 010 for ±10V, 420 for 4 to 20mA. | ||||
C | Loadcell excitation voltage | |||
05 for 5V, 10 for 10V. | ||||
D | Loadcell output in mV/V | |||
Usually 1.0 or 2.0, other values are possible. | ||||
Example: SY011I-420-10-2.0 This has a 4 to 20mA current output, 10V loadcell excitation and an input sensitivity of 2.0mV/V for full range. |
If the SY011 does not have all the functions you require the SGA or LCA20 Loadcell Amplifiers may be more suitable. An LCA20 data-sheet and an SGA data-sheet are available.
|
PDF data-sheet | Printable data-sheet. Right click on the link to download the file. |
---|---|
PDF instructions | Printable user instructions for the current output SY011. Right click on the link to download the file. |
PDF instructions | Printable user instructions for the voltage output SY011. Right click on the link to download the file. |