![]() Manufacturing loadcells since 1972 |
T24-ACM/SAe Loadcell Telemetry Data Acquisition Unit |
| Home | Profile | News | Products | Codes | Applications | Stock | Engineering | Contact |
|
|
This remote loadcell data acquisition unit provides high performance wireless measurement of loadcell outputs. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells. Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or a base station. The data acquisition unit uses a pair of standard alkaline D cells and is configured using free T24 Toolkit software which runs on a computer connected to a T24 base station. External powering is also possible with a suitable dc power supply. Using good quality alkaline batteries, a 700ohm loadcell, a 100ms sample time at 3 readings a second with 24 hours a day operation the battery life is approximately 18 days. The Toolkit software will calculate typical battery life for a given set of conditions. Loadcell connections are via field terminals. Full details are given in the manual. If the unit is supplied with a loadcell it will normally be calibrated to read the loadcell output in the same force units as the loadcell calibration. A traceable system certificate will be supplied for this calibration. The loadcell and this unit are the only parts of the telemetry system that require calibration. Alternative calibrations are possible; please consult our engineering department to discuss your requirements. The T24 system can be used with any of our loadcells. Details of our loadcell families can be found in the Loadcell Specifier Guide. Details of our loadcell families can be found in the Product List. |
|
| Description | Min | Typical | Max | Units |
| Battery voltage | 2.1 | 3 | 3.6 | Vdc |
| External dc supply | 5 | 18 | Vdc | |
| Bridge Excitation | 4.5 | 5 | 5.25 | Vdc |
| Loadcell Excitation System | 4 wire | |||
| Bridge Impedance | 85 | 5,000 | Ohms | |
| Bridge Sensitivity | -3.2 | +3.2 | mV/V | |
| Offset Temperature Stability | 1 | 4 | ppm/°C | |
| Gain Temperature Stability | 3 | 5 | ppm/°C | |
| Offset Stability with Time | 0.002 | 0.008 | %FR * | |
| Gain Stability with Time | 30 | ppm of FR /1st Year | ||
| Non-linearity | 0.0005 | 0.0025 | % FR | |
| Internal Resolution | 16 Million | Counts/Divisions | ||
| Resolution at 1000ms sample time * | 250,000 | Counts/Divisions | ||
| Resolution at 100ms sample time * | 120,000 | Counts/Divisions | ||
| Resolution at 10ms sample time * | 50,000 | Counts/Divisions | ||
| Maximum loadcell cable length | 3 |
m | ||
| Case dimensions | See diagram below | |||
| Operating temperature range | -10 | 50 | °C | |
| Storage temperature | -40 | 85 | °C | |
| Humidity | 0 | 95 | %RH Non condensing | |
| Sealing | IP65 | |||
Notes
Order CodeT24-ACM/SAe - Cased battery powered loadcell data acquisition unit. Supplied with a disc containing the T24 Toolkit program and user manuals. The T24 system can be calibrated in a number of different ways depending upon the application. Please consult our engineering department for help with your requirements. Please see Engineering Sheet E035 for Frequently Asked Questions for the T24 Telemetry system.
|
| PDF data-sheet | Printable data-sheet. Right click on the link to download the file if you are using Internet Explorer. |
|---|---|
| PDF instructions | Printable manual for the T24 data acquisition modules. Right click on the link to download the file if you are using Internet Explorer. |
Updated January 2012. |
© 1999-2012 Novatech
Measurements Limited. All rights reserved. |