This loadcell amplifier is designed for mounting inside the F256 and F257 loadcells. It is available in three versions, 2 wire 24V powered, 3 wire 12V powered and 3 wire 24V powered. The 2 wire version is only suitable for use with 2000ohm bridges.

On loadcells with bi-directional calibration the zero is set at 12mA.

Details of our loadcell families can be found in the Product Guide.

SY014 Specification

Output 4 to 20mA
Non-linearity - typical ±0.05% of full range
Supply requirements code Q 24Vdc (2 wire)
  code Z 12Vdc (3 wire)
  code Y 24Vdc (3 wire)
Operating Temperature 0 to +50°C

Additional Information

Engineering Engineering application sheet.
PDF instructions Printable user instructions for the two wire SY014. Right click on the link to download the file.
PDF instructions Printable user instructions for the three wire SY014. Right click on the link to download the file.

If the SY014 does not have all the functions you require the SGA or LCA20 Loadcell Amplifier may be more suitable. SGA and LCA20 data-sheets are available.

CEThis instrumentation product complies with the requirements of the European EMC directive.

Top