LCA15 Intelligent Loadcell Amplifier |
| Home | Profile | News | Products | Specifier | Codes | Applications | Stock | Engineering | Contact |
|
|
This intelligent self contained loadcell amplifier is designed for use with strain gauge loadcells. It provides industry standard current, voltage or serial data signals for accurate interfacing of loadcells with control and monitoring systems. All set up functions are via the programming module using a simple menu system. The module can be mounted on the amplifier board or supplied as a separate hand held unit for use with more than one amplifier. All parameters are set digitally for accuracy, including the analogue output. The 4 to 20mA and 0 to 10V outputs can both be used at the same time but only one can be accurately calibrated. See the LCA15 specification for more information. The normal set-up is to calibrate the 4 to 20mA output accurately unless special instructions are given with an order. The analogue output is uni-polar so if a bi-directional loadcell is used the only way to scale the amplifier is to set the mid-point of the analogue output equal to zero load. This will be 12mA or 5V. This amplifier is used throughout the process industry providing a local transmitter for process vessels and within the engineering industry for single or multiple loadcell applications. An option is available for RS232/RS485 serial communication single links or multi-drop applications of up to 25 weigh stations. This amplifier can be used with any of our loadcells. Details of our loadcell families can be found in the Loadcell Specifier Guide. |
|
| Sensitivity | 0.5 to 200mV/V |
| Conversion rate | 10 readings per second |
| Accuracy | 90 days ±0.08% of reading ±0.05% of FSD typical |
| Drift | 0.002% full range/ °C typical at 2.5mV/V |
| Analogue output | 4 to 20mA, loop resistance <1k0Ω - typical accuracy 0.15% of
range.
0 to 10V, load resistance >5k0Ω - accurate to within 2% of 4 to 20mA |
| Settling time | 0.25 secs to 1% of step change |
| Loadcell supply | 9.6Vdc at 150mA (4 x 350Ω loadcells), with remote sensing |
| Operating Temperature | -10 to +50°C |
| Storage temperature | -20 to +70°C |
| Case sealing | IP65 |
| Supply requirements | 115/230Vac (LS1) or 9-32Vdc (LS3), power 10 Watts |
| LCA15-LS1 | Basic amplifier in an ABS IP65 case - 200 x 120 x 75mm. |
Note: The basic amplifier does not include
a programmer module - see below. |
|
| -LC3 | RS232/RS485 serial communications. This can be configured for use with a printer or a computer. |
| -LR1 | 2 set points. Each set point has a SPCO relay contact rated at 5A 240Vac, resistive load. |
| -LTL | ABS case with a transparent lid |
| -LSS | Stainless steel case - 220 x 160 x 85mm |
| Supplied with an operators manual giving full details of the programmable parameters. The parameters are stored in non-volatile memory. When the LCA15 is purchased with a loadcell the amplifier will be calibrated with appropriate scaling for use with the loadcell. |
| LP1 | Board mounted programmer - 4½ digit display |
| LP2 | Hand held programmer - 4½ digit display |
|
This product complies with the requirements of the European EMC directive. |
| Outline | Outline drawing of the product. |
|---|---|
| PDF data-sheet | Printable data-sheet. Right click on the link to download the file if you are using Internet Explorer. |
| PDF manual | Printable manual. Right click on the link to download the file if you are using Internet Explorer. |
Updated July 2008. |
© 1999-2008 Novatech