F327 Donut LoadcellStandard Ranges 10, 20, 50, 100, 200, 500, 1000 and 2000kN (1 to 200tonne) |
| Home | Profile | News | Products | Specifier | Codes | Applications | Stock | Engineering | Contact |
|
|
The F327 is a robust canister loadcell that is ideally suited to compression force measurement applications in harsh conditions. The loadcell is deliberately over engineered to achieve a low contact surface pressure under high loading. Smaller column type loadcells, such as the F218, are available and we can cover the F327 load ranges with smaller designs. Please consult our engineering department. Details of our other loadcell families can be found in the Loadcell Specifier Guide. |
|
| See the loadcell ordering code sheet for more details. Add range in the required force units. | |||
| F327CFS0K0 | Compression, IP67, unrationalised | F327CFS0KN | Compression, IP67, rationalised |
| Change the F to a P for the connector version. | |||
| Parameter | 10 - 50kN | 100 - 2000kN | Unit |
|---|---|---|---|
| Non-linearity - Terminal | ±0.05 | ±0.1 | % RL |
| Hysteresis | ±0.05 | ±0.4 | % RL |
| Creep - 20 minutes | ±0.05 | ±0.05 | % AL |
| Repeatability (excluding rotational effects)* | ±0.02 | ±0.03 | % RL |
| Rated output - Nominal | 1.2 | 1.2 | mV/V |
| Rated output - Rationalised | 1.0 | 1.0 | mV/V |
| Rationalisation tolerance | ±0.5 | ±0.5 | % RL |
| Zero load output | ±4 | ±4 | % RL |
| Temperature effect on rated output per °C | ±0.005 | ±0.005 | % AL |
| Temperature effect on zero load output per °C | ±0.01 | ±0.01 | % RL |
| Temperature range - Compensated | -10 to +50 | -10 to +50 | °C |
| Temperature range - Safe | -10 to +80 | -10 to +80 | °C |
| Excitation voltage - Recommended | 10 | 10 | V |
| Excitation voltage - Maximum | 20 | 20 | V |
| Bridge resistance | 700 | 700 | Ω |
| Insulation resistance - Minimum at 50Vdc | 500 | 500 | MΩ |
| Overload - Safe | 50 | 50 | % RL |
| Overload - Ultimate | 200 | 200 | % RL |
| Sealing | IP67 | IP67 | |
| Weight - Nominal (excluding cable) | 1.6 | 8 to 28.3 | kg |
All standard ranges are manufactured in stainless steel.
* Repeatability errors will increase if the loadcell is rotated to ±0.06% of RL
| Range (kN) | Stiffness (N/m) | Range (kN) | Stiffness (N/m) | Range (kN) | Stiffness (N/m) |
|---|---|---|---|---|---|
| 10 | 2.2 x 108 | 100 | 1.6 x 109 | 1000 | 8.3 x 109 |
| 20 | 4.3 x 108 | 200 | 3.2 x 109 | 2000 | 8.7 x 109 |
| 50 | 1.1 x 109 | 500 | 8.1 x 109 |
Notes
ConnectionsThe loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 16-2-4C or a 4 pin Binder 723 series chassis plug. Excitation + = Red or pin 1, Excitation - = Blue or pin 2, Signal + = Yellow or pin 3, Signal - = Green or pin 4, Screen = Orange. The screen is not connected to the loadcell body. |
| Outline | Outline drawing of the product. |
|---|---|
| PDF data-sheet | Printable data-sheet. Right click on the link to download the file if you are using Internet Explorer. |
Updated January 2010. |
© 1999-2010 Novatech