• Very high precision
  • Precision alignment tool facility
  • Standard bearing mounting
  • Mounting foot provision
  • Optional mounting flange

F325 High Accuracy Web Tension Loadcell

This high precision web tension loadcell is designed and built to meet the needs of machine designers, installation fitters and end users by the incorporation of alignment features with maximum flexibility. The high performance of this loadcell is not compromised by the relatively large errors that can be produced by imprecise installation.

We are happy to design variants of this loadcell to meet your specific requirements.

Details of our other loadcell families can be found in the Loadcell Specifier Guide.

Ordering Codes
See the loadcell ordering code sheet for more details. Add range in the required force units.
F325CF00K0 Compression, unrationalised
F325 Specification
Parameter Value Unit
Non-linearity - Terminal ±0.03 % RL
Hysteresis ±0.03 % RL
Creep - 20 minutes ±0.05 % AL
Repeatability ±0.01 % RL
Rated output - Nominal 1.2 mV/V
Rated output - Rationalised 1.0 mV/V
Rationalisation tolerance ±0.1 % RL
Zero load output ±4 % RL
Temperature effect on rated output per °C ±0.005 % AL
Temperature effect on zero load output per °C ±0.01 % RL
Temperature range - Compensated -10 to +50 °C
Temperature range - Safe -10 to +80 °C
Excitation voltage - Recommended 10 V
Excitation voltage - Maximum 10 V
Bridge resistance 350 Ω
Insulation resistance - Minimum at 50Vdc 500
Overload - Safe 50 % RL
Overload - Ultimate 200 % RL
Weight - Nominal (excluding cable) 380 g

The standard ranges are manufactured in aluminium alloy.

Structural stiffness - Nominal
Range (N) Stiffness (N/m) Range (N) Stiffness (N/m) Range (N) Stiffness (N/m)
50 8.3 x 105 200 1.5 x 106    
100 1.1 x 106 500 2.0 x 106    

Notes

  1. AL = Applied load.
  2. RL = Rated load.
  3. Temperature coefficients apply over the compensated range.

Connections

The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

The screen is not connected to the loadcell body.

Additional Information
Outline Outline drawing of the product.
PDF data-sheet Printable data-sheet. Right click on the link to download the file if you are using Internet Explorer.