• Off centre loading compensation
  • Simple cable tie or screw fixing
  • Anti-slip rubber pad
  • Removable loading plate
  • Output rationalised to 2mV/V
  • Lightweight aluminium alloy construction

F323 Clutch Pedal Force Loadcell

The F323 is a compact, high accuracy low profile loadcell for measuring clutch pedal application forces. The loadcell is robust in construction with a maximum force range of 1kN (100kg). Its multi-hole fixing allows simple attachment to any shape pedal using screws or cable ties. The low profile design maintains the clutch pedals ergonomic geometry. Low mass aluminium alloy construction reduces the mass influence upon the clutch pedal in dynamic testing.

Additional information can be found in the Pedal Force Engineering Application Sheet. If you require other force ranges the F304 or F322 may be suitable.

We are happy to design variants of this loadcell to meet your specific requirements.

Details of our other loadcell families can be found in the Loadcell Specifier Guide.

Ordering Codes
See the loadcell ordering code sheet for more details. Add range in the required force units.
F323CFR0KN Compression, IP65, rationalised
F323 Specification
Parameter Value Unit
Non-linearity - Terminal ±0.05 % RL
Hysteresis ±0.05 % RL
Creep - 20 minutes ±0.05 % AL
Repeatability ±0.02 % RL
Rated output - Rationalised 2.0 mV/V
Rationalisation tolerance ±0.1 % RL
Zero load output ±4 % RL
Temperature effect on rated output per °C ±0.002 % AL
Temperature effect on zero load output per °C ±0.005 % RL
Temperature range - Compensated -10 to +50 °C
Temperature range - Safe -10 to +80 °C
Excitation voltage - Recommended 10 V
Excitation voltage - Maximum 20 V
Bridge resistance 700 Ω
Insulation resistance - Minimum at 50Vdc 500
Inclined load error - concentric at 3° ±0.25 % RL
Structural stiffness 1.5 x 107 N/m
Overload - Safe 50 % RL
Overload - Ultimate 200 % RL
Sideload - Safe 100 % RL
Sealing IP65  
Weight - Nominal (excluding cable) 80 g

The standard range is manufactured in aluminium alloy.

Notes

  1. AL = Applied load.
  2. RL = Rated load.
  3. Temperature coefficients apply over the compensated range.

Connections

The loadcell is fitted with 2 metres of flexible polyurethane jacketed 4 core screened cable.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

The screen is not connected to the loadcell body.