F313 Low Profile Donut LoadcellStandard Ranges 1, 2, 4, 8, 10, 12, 16 and 20tonne (10 to 200kN) |
| Home | Profile | News | Products | Specifier | Codes | Applications | Stock | Engineering | Contact |
|
|
Geometry: Axial strain cylinder in weather sealed case, with raised end load bearing faces and hole right through. For use in compression or in fail-safe tensile applications on a wide range of OEM or end-user applications. The F313 is ideally suited to engineering force measurements. It is designed for easy installation, usually between two flat faces bearing on its loading rings, either unattached or with retaining spigots positioned in the centre hole. Alternatively tensile load transfer can be achieved via a tie rod assembly through the centre hole. In this way the loadcell can indirectly measure tensile loads in a "fail-safe" mode. We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for fully compensated operation up to +250°C. Please consult our engineering department. Details of our other loadcell families can be found in the Loadcell Specifier Guide. |
|
| See the loadcell ordering code sheet for more details. Add range in the required force units. | |||
| F313CFR0K0 | Compression, IP65, unrationalised | F313CFR0KN | Compression, IP65, rationalised |
| Change the K to an H for the 1 tonne range. | |||
| Parameter | 1tonne | 2 - 20tonne | Unit |
|---|---|---|---|
| Non-linearity - Terminal | ±0.5 | ±0.5 | % RL |
| Hysteresis | ±0.5 | ±0.5 | % RL |
| Creep - 20 minutes | ±0.1 | ±0.1 | % AL |
| Repeatability (excluding rotational effects) | ±0.1 | ±0.1 | % RL |
| Rated output - Nominal | 1.3 | 1.3 | mV/V |
| Rated output - Rationalised | 1.0 | 1.0 | mV/V |
| Rationalisation tolerance | ±0.5 | ±0.5 | % RL |
| Zero load output | ±4 | ±4 | % RL |
| Temperature effect on rated output per °C | ±0.005 | ±0.005 | % AL |
| Temperature effect on zero load output per °C | ±0.03 | ±0.03 | % RL |
| Temperature range - Compensated | -10 to +50 | -10 to +50 | °C |
| Temperature range - Safe | -10 to +80 | -10 to +80 | °C |
| Excitation voltage - Recommended | 10 | 10 | V |
| Excitation voltage - Maximum | 10 | 20 | V |
| Bridge resistance | 350 | 700 | Ω |
| Insulation resistance - Minimum at 50Vdc | 500 | 500 | MΩ |
| Overload - Safe | 50 | 50 | % RL |
| Overload - Ultimate | 400 | 400 | % RL |
| Sealing | IP65 | IP65 | |
| Weight - Nominal (excluding cable) | 15 | 20-260 | g |
All standard ranges are manufactured in stainless steel.
| Range (kN) | Stiffness (N/m) | Range (kN) | Stiffness (N/m) | Range (kN) | Stiffness (N/m) |
|---|---|---|---|---|---|
| 10 | 1.1 x 109 | 80 | 8.8 x 109 | 160 | 8.0 x 109 |
| 20 | 2.2 x 109 | 100 | 7.7 x 109 | 200 | 1.0 x 1010 |
| 40 | 4.4 x 109 | 120 | 7.1 x 109 |
Notes
ConnectionsFor ranges up to 4 tonnes the loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-1-4C. Ranges above 4 tonnes are fitted with 7-2-4C cable. Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange. The screen is not connected to the loadcell body. When this loadcell is rationalised the resistors are housed in a capsule located in the loadcell cable 100mm from the free end. Capsule dimensions are Ø10mm by 57mm. |
| Outline | Outline drawing of the product. |
|---|---|
| Stock List | Loadcells normally available for despatch within 24 hours. |
| PDF data-sheet | Printable data-sheet. Right click on the link to download the file if you are using Internet Explorer. |
Updated July 2008. |
© 1999-2008 Novatech