We can manufacture shear pin loadcells to your specific requirements. If you fill in the blanks on the form below and send it to our sales department we will respond with a quotation, usually within 24 hours. If the standard value for any parameter is suitable you can leave the field blank. We need at least one contact number or email address to return the quotation! More information can be found in the F312 Engineering Application Sheet.

F312 Custom Shear Pin Loadcell
Company: Tel:
Contact: Fax:
Quantity: Email:
Required Dimensions (mm)
Ø L1 L3 DEPTH
L L2 L4 L5
Parameter Typical Value Required Value Unit
Load range - tonnef
Non-linearity - Terminal ±0.1 to ±0.3 % RL
Repeatability ±0.1 % RL
Rated output - Nominal 2.2 mV/V
Zero load output ±4 % RL
Temperature effect on rated output per °C ±0.005 % AL
Temperature effect on zero load output per °C ±0.005 % RL
Temperature range - Compensated -10 to +50 °C
Temperature range - Safe -10 to +80 °C
Excitation voltage - Recommended 10 V
Bridge resistance 350 Ω
Insulation resistance - Minimum at 50Vdc 500
Overload - Safe 50 % RL
Overload - Ultimate 100 % RL
Sealing IP65  
Cable length 2 m
Delete all the information that you have entered so that you can start again.
Send the information to Novatech Measurements for a quotation.

Notes

  1. AL = Applied load.
  2. RL = Rated load.
  3. Temperature coefficients apply over the compensated range.

Top