• Very low profile
  • Universal fixing
  • Hardened stainless steel
  • Sealed to IP65
  • Standard 2 year warranty

F302 Low Profile Diaphragm Loadcell

Geometry: Low profile axial loadcell for use in force measurements in compression.

The F302 is designed for force measurement in compression. The loadcell is designed for simple mounting on a smooth flat surface. It has an integral load button and is supplied with three tapped holes and three clearance holes enabling fixing or location from either above or below the loadcell.

In the event of structural failure of the loadcell the resulting vertical movement of the supported load will be very small.

We are happy to design variants of this loadcell to meet your specific requirements. Please consult our engineering department.

Details of our other loadcell families can be found in the Loadcell Specifier Guide.

Ordering Codes
See the loadcell ordering code sheet for more details. Add range in the required force units.
F302CFROHN Compression, IP65, rationalised
F302 Specification
Parameter Value Unit
Non-linearity - Terminal ±0.5 % RL
Hysteresis ±0.3 % RL
Creep - 20 minutes ±0.05 % AL
Repeatability ±0.1 % RL
Rated output - Rationalised 2.0 mV/V
Rationalisation tolerance ±0.5 % RL
Zero load output ±4 % RL
Temperature effect on rated output per °C ±0.005 % AL
Temperature effect on zero load output per °C ±0.005 % RL
Temperature range - Compensated -10 to +50 °C
Temperature range - Safe -10 to +80 °C
Excitation voltage - Recommended 10 V
Excitation voltage - Maximum 10 V
Bridge resistance 350 Ω
Insulation resistance - Minimum at 50Vdc 500
Overload - Safe 50 % RL
Overload - Ultimate 300 % RL
Sealing IP65  
Weight - Nominal (excluding cable) 78 to 90 g

All standard ranges are manufactured in stainless steel.

Structural stiffness - Nominal
Range (kN) Stiffness (N/m) Range (kN) Stiffness (N/m) Range (kN) Stiffness (N/m)
5 1.0 x 108 25 1.1 x 109    
10 2.9 x 108 50 2.2 x 109    

Notes

  1. AL = Applied load.
  2. RL = Rated load.
  3. Temperature coefficients apply over the compensated range.
  4. The load must be applied directly through the central loading axis.

Connections

The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-1-4C.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

The screen is not connected to the loadcell body.

When this loadcell is rationalised the resistors are housed in a capsule located in the loadcell cable 100mm from the free end. Capsule dimensions are Ø10mm by 57mm.

Additional Information
Outline Outline drawing of the product.
Stock List Loadcells normally available for despatch within 24 hours.
PDF data-sheet Printable data-sheet. Right click on the link to download the file if you are using Internet Explorer.