F241 Axial Compensated LoadcellStandard Ranges 3, 5, 10 and 30kg (30 to 300N ) |
| Home | Profile | News | Products | Specifier | Codes | Applications | Stock | Engineering | Contact |
|
|
Geometry: Flexure strain assembly in cylindrical housing, open or weather sealed with end internal fixing. For universal use in tension and compression, with compensation for off axis load inputs. The F241 is ideally suited to low range engineering force measurements and process weighing. When precision and easy installation are required various configurations allow the loadcell to be used in both tensile and compressive applications. We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for higher temperature operation. Please consult our engineering department. Details of our other loadcell families can be found in the Loadcell Specifier Guide. |
|
| See the loadcell ordering code sheet for more details. Add range in the required force units. | |||
| F241CF00H0 | Compression, unrationalised | F241CF00HN | Compression, rationalised |
| F241TF00H0 | Tension, unrationalised | F241TF00HN | Tension, rationalised |
| F241UF00H0 | Bi-directional, unrationalised | F241UF00HN | Bi-directional, rationalised |
| Change the first 0 to an R for the IP65 version. | Change the C to a D for compression with thread fitting. | ||
| If the overload stop option is required add this to the description. | |||
| Parameter | Value | Unit |
|---|---|---|
| Non-linearity - Terminal | ±0.05 | % RL |
| Hysteresis | ±0.05 | % RL |
| Creep - 20 minutes | ±0.02 | % AL |
| Repeatability | ±0.02 | % RL |
| Rated output - Nominal | 2.2 | mV/V |
| Rated output - Rationalised | 2.0 | mV/V |
| Rationalisation tolerance | ±0.1 | % RL |
| Zero load output | ±4 | % RL |
| Temperature effect on rated output per °C | ±0.002 | % AL |
| Temperature effect on zero load output per °C | ±0.005 | % RL |
| Temperature range - Compensated | -10 to +50 | °C |
| Temperature range - Safe | -10 to +80 | °C |
| Excitation voltage - Recommended | 10 | V |
| Excitation voltage - Maximum | 10 | V |
| Bridge resistance | 350 | Ω |
| Insulation resistance - Minimum at 50Vdc | 500 | MΩ |
| Overload - Safe | 20 | % RL |
| Overload - Ultimate | 100 | % RL |
| Weight - Nominal (excluding cable) | 240 to 260 | g |
All standard ranges are manufactured in aluminium.
| Range (N) | Stiffness (N/m) | Range (N) | Stiffness (N/m) | Range (N) | Stiffness (N/m) |
|---|---|---|---|---|---|
| 30 | 1.5 x 105 | 100 | 5.0 x 105 | ||
| 50 | 2.5 x 105 | 300 | 1.5 x 106 |
Notes
ConnectionsThe loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C. Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange. Reverse the signal connections to obtain a positive signal in tension mode. The screen is not connected to the loadcell body. |
| Outline | Outline drawing of the product. |
|---|---|
| PDF data-sheet | Printable data-sheet. Right click on the link to download the file. |
Updated January 2008. |
© 1999-2008 Novatech