F225 High Load Ultra Low Profile LoadcellStandard Ranges 5 and 10tonne (50 and 100kN) |
| Home | Profile | News | Products | Specifier | Codes | Applications | Stock | Engineering | Contact |
|
|
Geometry: Ultra low profile axial loadcell for use in force measurements in compression. The ultra slim design provides for ease of installation beneath heavy machinery mounts, hydraulic rams or interposed within series mechanical compression assemblies. In the event of structural failure of the loadcell the resulting vertical movement of the supported load including normal deflection will not exceed 2.5mm. We are happy to design variants of this loadcell to meet your specific requirements. Please consult our engineering department. Details of our other loadcell families can be found in the Loadcell Specifier Guide. |
|
| See the loadcell ordering code sheet for more details. Add range in the required force units. | |||
| F225CFR0H0 | Compression, IP65, unrationalised | F225CFR0HN | Compression, IP65, rationalised |
| Change the R to an S for IP67 sealing. | |||
| Parameter | Value | Unit |
|---|---|---|
| Non-linearity - Terminal | ±0.5 | % RL |
| Hysteresis | ±0.5 | % RL |
| Creep - 20 minutes | ±0.05 | % AL |
| Repeatability | ±0.02 | % RL |
| Rated output - Nominal | 2.3 | mV/V |
| Rated output - Rationalised | 2.0 | mV/V |
| Rationalisation tolerance | ±0.5 | % RL |
| Zero load output | ±4 | % RL |
| Temperature effect on rated output per °C | ±0.005 | % AL |
| Temperature effect on zero load output per °C | ±0.005 | % RL |
| Temperature range - Compensated | -10 to +50 | °C |
| Temperature range - Safe | -10 to +80 | °C |
| Excitation voltage - Recommended | 10 | V |
| Excitation voltage - Maximum | 10 | V |
| Bridge resistance | 350 | Ω |
| Insulation resistance - Minimum at 50Vdc | 500 | MΩ |
| Overload - Safe | 50 | % RL |
| Overload - Ultimate | 300 | % RL |
| Sealing - R option | IP65 | |
| Sealing - S option | IP67 | |
| Weight - Nominal (excluding cable) | 0.8 | kg |
All standard ranges are manufactured in stainless steel.
| Range (kN) | Stiffness (N/m) | Range (kN) | Stiffness (N/m) | Range (kN) | Stiffness (N/m) |
|---|---|---|---|---|---|
| 50 | 2.1 x 1010 | 100 | 4.2 x 1010 |
Notes
ConnectionsThe loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C. Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange. The screen is not connected to the loadcell body. |
| Outline | Outline drawing of the product. |
|---|---|
| PDF data-sheet | Printable data-sheet. Right click on the link to download the file. |
Updated January 2008. |
© 1999-2008 Novatech