• Ultra low profile
  • Fail-safe failure mode
  • Hardened stainless steel
  • IP67 sealing option
  • Traceable calibration with certificate included in the standard price
  • Standard 2 year warranty

F225 High Load Ultra Low Profile Loadcell

Geometry: Ultra low profile axial loadcell for use in force measurements in compression.

The ultra slim design provides for ease of installation beneath heavy machinery mounts, hydraulic rams or interposed within series mechanical compression assemblies.

In the event of structural failure of the loadcell the resulting vertical movement of the supported load including normal deflection will not exceed 2.5mm.

We are happy to design variants of this loadcell to meet your specific requirements. Please consult our engineering department.

Details of our other loadcell families can be found in the Product Guide.

Ordering Codes

See the loadcell ordering code sheet for more details. Add range in the required force units.
F225CFR0H0 Compression, IP65, unrationalised F225CFR0HN Compression, IP65, rationalised
Change the R to an S for IP67 sealing.

F225 Specification

Parameter Value Unit
Non-linearity - Terminal ±0.5 % RL
Hysteresis ±0.5 % RL
Creep - 20 minutes ±0.05 % AL
Repeatability ±0.02 % RL
Rated output - Nominal 2.3 mV/V
Rated output - Rationalised 2.0 mV/V
Rationalisation tolerance ±0.5 % RL
Zero load output ±4 % RL
Temperature effect on rated output per °C ±0.005 % AL
Temperature effect on zero load output per °C ±0.005 % RL
Temperature range - Compensated -10 to +50 °C
Temperature range - Safe -10 to +80 °C
Excitation voltage - Recommended 10 V
Excitation voltage - Maximum 10 V
Bridge resistance 350 Ω
Insulation resistance - Minimum at 50Vdc 500
Overload - Safe 50 % RL
Overload - Ultimate 300 % RL
Sealing - R option IP65  
Sealing - S option IP67  
Weight - Nominal (excluding cable) 0.8 kg 

All standard ranges are manufactured in stainless steel.

Structural stiffness - Nominal

Range (kN) Stiffness (N/m) Range (kN) Stiffness (N/m) Range (kN) Stiffness (N/m)
50 2.1 x 1010 100 4.2 x 1010    

Notes

  1. AL = Applied load.
  2. RL = Rated load.
  3. Temperature coefficients apply over the compensated range.
  4. The load must be applied directly through the central loading axis.

Connections

The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

The screen is not connected to the loadcell body.

Additional Information

Outline Outline drawing of the product.
STEP file STEP files for standard ranges.
Stock List Loadcell availability.
PDF data-sheet Printable data-sheet. Right click on the link to download the file.

Top