• Low profile with centre hole
  • Ranges to suit bolt sizes from M6 to M36
  • Stainless steel construction
  • Tensile applications are ‘fail-safe’
  • Traceable calibration with certificate included in the standard price
  • Standard 2 year warranty

F207 Load Washer

Geometry: Axial strain cylinder in weather sealed case, with raised end load bearing faces and hole right through. For use in compression or in fail-safe tensile applications on a wide range of OEM or end-user applications.

The F207 is ideally suited to engineering force measurements where overall height is restricted; if a slight increase in height is acceptable the F313 may be a better choice.

It is designed for easy installation, usually between two flat faces bearing on its loading rings, either unattached or with retaining spigots positioned in the centre hole. Alternatively tensile load transfer can be achieved via a tie rod assembly through the centre hole. In this way the loadcell can indirectly measure tensile loads in a "fail-safe" mode.

We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for fully compensated operation up to +250°C. Please consult our engineering department.

Details of our other loadcell families can be found in the Product Guide.

Ordering Codes

See the loadcell ordering code sheet for more details. Add range in the required force units.
F207CFR0K0 Compression, IP65, unrationalised F207CFR0KN Compression, IP65, rationalised
Change the K to an H for the 1 tonnef range.

F207 Specification

Parameter 10kN 20 - 200kN Unit
Non-linearity - Terminal ±2.0 ±2.0 % RL
Hysteresis ±2.0 ±2.0 % RL
Creep - 20 minutes ±0.1 ±0.1 % AL
Repeatability (valid for a fixed loadcell position with no rotation) ±0.2 ±0.2 % RL
Rated output - Nominal 1.3 1.3 mV/V
Rated output - Rationalised 1.0 1.0 mV/V
Rationalisation tolerance ±1.0 ±1.0 % RL
Zero load output ±4 ±4 % RL
Temperature effect on rated output per °C ±0.005 ±0.005 % AL
Temperature effect on zero load output per °C ±0.03 ±0.03 % RL
Temperature range - Compensated -10 to +50 -10 to +50 °C
Temperature range - Safe -10 to +80 -10 to +80 °C
Excitation voltage - Recommended 10 10 V
Excitation voltage - Maximum 10 20 V
Bridge resistance 350 700 Ω
Insulation resistance - Minimum at 50Vdc 500 500
Overload - Safe 50 50 % RL
Overload - Ultimate 400 400 % RL
Sealing IP65 IP65  
Weight - Nominal (excluding cable) 15 20-260 g

All standard ranges are manufactured in stainless steel.

Structural stiffness - Nominal

Range (kN) Stiffness (N/m) Range (kN) Stiffness (N/m) Range (kN) Stiffness (N/m)
10 1.1 x 109 80 8.8 x 109 160 8.0 x 109
20 2.2 x 109 100 7.7 x 109 200 1.0 x 1010
40 4.4 x 109 120 7.1 x 109    

Notes

  1. AL = Applied load.
  2. RL = Rated load.
  3. Temperature coefficients apply over the compensated range.
  4. The load must be applied directly through the central loading axis.

Connections

For ranges up to 4 tonnefs the loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-1-4C. Ranges above 4 tonnefs are fitted with 7-2-4C cable.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

The screen is not connected to the loadcell body.

When this loadcell is rationalised the resistors are housed in a capsule located in the loadcell cable 100mm from the free end. Capsule dimensions are Ø10mm by 57mm.

Additional Information

Outline Outline drawing of the product.
STEP file STEP files for standard ranges.
Stock List Loadcell availability.
PDF data-sheet Printable data-sheet. Right click on the link to download the file.