![]() Manufacturing loadcells since 1972 |
Pinch And Pull Force Measurement |
| Home | Profile | News | Products | Codes | Applications | Stock | Technical Information | Contact |
|
|
A UK based University School of Sport Science required a force measurement system to measure pinch force when pulling against a fixed structure. The system would be mounted in a Magnetic Resonance Imaging (MRI) scanner and therefore must be of a non-ferrous construction. As the research budget was limited, the overall cost for the system was important. Novatech was able to offer a low cost solution using two pre-existing loadcell designs held together using a removable fixing plate. This allowed flexibility to change the dimensions of the fixing plate or to use the two loadcells separately Construction was aluminium with brass fittings to produce a system unaffected by the magnetic field produced in the MRI unit.
|
|
| PDF version | Printable version. Right click on the link to download the file if you are using Internet Explorer. |
|---|
Updated September 2008. |
© 1999-2013 Novatech